PowMr Hybrid Solar Inverter 3.2KW 3.0KW 2.0KW 24V 12V Photovoltaic Hybrid Inverter 230VAC Max PV 400V Build in 80A MPPT Charger

$209.05$359.97

Compare
SKU: cmamumq4e43000catoog Category:

Description

SPECIFICATIONS


Brand Name: PowMr

Origin: Mainland China

Certification: CE

Size: 348x270x95 mm

Output Frequency: 50HZ/60HZ

Output Type: single

is_customized: Yes

Output Current: MPPT 80A

Output Power: 1 – 200KW

Weight: 5.8KG

Is Smart Device: YES

Model Number: POW-HVM H Series

Item: solar inverter

Product: hybrid solar inverter

Description: photovoltaic hybrid inverter

Charging: pure sine wave inverter

Work for: solar Panel/Photovoltaic Panel

Part of: solar system complete

Rated output power: 3000W/3000W/1600W

Output voltage range: 230VAC

Working efficiency: >95%

Maximum PV input current: 18A

Maximum PV input power: 3200W/3000W/2000W

Battery voltage: 24V/12V

Battery type:: Lifepo4, Lithium, Flooded, Gel, Lead-acid Batteries

Load type: Household appliances, farm tools, farm tools

Applicable equipment: Factory equipment, commercial load, industrial machinery

Applicable area: Asia, Europe, Africa and North America (220-240VAC drivers)

Feature: Support wifi module

Shipping 1:: EU customers purchase from China, and the system automatically sends packages from Europe.

Shipping 2: Within 3-7 days, the package arrive.


PowMr Hybrid Solar Inverter 3.2KW 3.0KW 1.6KW 12V 24V Photovoltaic Hybrid Inverter 230VAC Max PV 400V Build in 80A MPPT Charger

Introduction:

This is a multi-function inverter/charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support with portable size.

Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Features:

• Pure sine wave inverter
• Configurable input voltage range for home appliances and personal computers via LCD setting
• Configurable battery charging current based on applications via LCD setting
• Configurable AC/Solar Charger priority via LCD setting
• Compatible with mains voltage or generator power
• Auto restart while AC is recovering
• Overload/ Over temperature/ short circuit protection
• Smart battery charger design for optimized battery performance
• Cold start function
• WIFI/GPRS(Option)
• Can connect to lithium battery

Specifications:

INVERTER MODEL

POW-HVM2H-12V-N

POW-HVM3.0KW-24V

POW-HVM3.2H-24V-N

Rated Output Power

2000VA1600W

3200VA/3000W

3200VA/3000W

Output Voltage Waveform

Pure Sine Wave

Output Voltage Regulation

230Vac±5%

Utility Charging Mode

INVERTER MODEL

2.0KW 12V

3.0KW 24V

3.2KW 24V

Charging Algorithm

3-Step

AC Charging Current (Max)

60 Amp

Bulk Charging Voltage

INVERTER MODEL

2.0KW 12V

3.0KW 24V

3.2KW 24V

Flooded Battery

14.6

29.2

AGM / Gel Battery

14.1

28.2

Floating Charging Voltage

13.5Vdc

27.0Vdc

MPPT Solar Charging Mode

Max. PV Array Power

2000W

3000W

3000W

Nominal PV Voltage

240Vdc

PV Array MPPT Voltage Range

30~400Vdc

90~430Vdc

30~400Vdc

Max. PV Array Open Circuit Voltage

400Vdc

450Vdc

400Vdc

Max Charging Current (AC charger+solar charger)

80Amp

INVERTER MODEL

2.0KW 12V

3.0KW 24V

3.2KW 24V

Safety Certification

CE

Operating Temperature Range

-10±C to 50±C

Storage temperature

-15±C~ 60± C

Humidity

5% to 95% Relative Humidity (Non-condensing)

Input Voltage Waveform

Sinusoidal (utility or generator)

Nominal Input Voltage

230Vac

Low Loss Voltage

170Vac±7V (UPS); 90Vac±7V (Appliances)

Low Loss Return Voltage

180Vac±7V (UPS);

100Vac±7V (Appliances)

High Loss Voltage

280Vac±7V

High Loss Return Voltage

270Vac±7V

Max AC Input Voltage

300Vac

Nominal Input Frequency

50Hz/ 60Hz (Auto-detection)

Low Loss Frequency

40±Hz

Low Loss Return Frequency

42±Hz

High Loss Frequency

65±Hz

High Loss Return Frequency

63±Hz

Output Short Circuit Protection

Circuit Breaker

Efficiency (Line Mode)

>95% ( Rated R load, battery full charged )

Transfer Time

10ms typical (UPS);

20ms typical (Appliances)

INVERTER MODEL

2.0KW 12V

3.0KW 24V

3.2KW 24V

Output Frequency

50Hz/ 60Hz (Auto-detection)

Peak Efficiency

94%

Overload Protection

5s@ >150% Io ad; 10s@ 110% ~ 150% Io ad

Surge Capacity

2* rated power for 5 seconds

Nominal DC Input Voltage

12Vdc

24Vdc

Cold Start Voltage

11.5Vdc

23.0Vdc

Low DC Warning Voltage

@ Io ad < 50>%

11.0Vdc

22.0Vdc

@ load >50%

10.5Vdc

21.0Vdc

Low DC Warning Return Voltage

@ load < 50%

11.5Vdc

22.5Vdc

@ load >50%

11.0Vdc

22.0Vdc

Low DC Cut off Voltage

@ load < 50%

10.2Vdc

20.5Vdc

@ load >50%

9.6Vdc

20.0Vdc

High DC Recovery Voltage

14.0Vdc

29Vdc

32Vdc

High DC Cut-off Voltage

16.0Vdc

31Vdc

33Vdc

No Load Power Consumption

<25W

<30W

<35W

Product Overview: