Description
SPECIFICATIONS
Brand Name: PowMr
Origin: Mainland China
Certification: CE
Certification: FCC
Certification: RoHS
Output Frequency: 50Hz 60Hz
Output Type: single
is_customized: Yes
Output Current: 120A
Output Power: 1 – 200KW
Is Smart Device: YES
Model Number: POW-HVM-M
Charge Current: MPPT 120A
Max PV Voltage: 500V
Max PV Power: 6200W 6500W
Grid Tie: On Grid
AC Voltage: 220V 230V 240V
DC Voltage: 24V 48V
Build In: MPPT Charge Controller
Output Voltage Waveform: Pure Sine Wave
Type 1: Grid Tie Inverter with Limiter
Type 2: On Grid Solar Inverter
Type 3: Hybrid Solar Inverter 24V 48V
PowMr Grid-Tie Hybrid Solar Inverter is a new all-in-one inverter bulit in MPPT charge controller, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support in a single device.
-
【Extend the life of loads】This solar hybrid inverter uses advanced pure sine wave technology that supplies electrical devices with high quality and stable AC current, protects electronic products or electrical appliances and extends the service life.
-
【LCD display and real-time monitoring】solar inverter has an LCD display that can display system data and operating status in real time. If you encounter a problem during use, the corresponding error code is displayed, which can help you fix the error easily. In addition, the inverter has LED indicators that let you know the operation of the inverter at a glance, which is very practical.
-
【3 Safe Charging Modes】The Inverter Charger offers versatile power customization, with 3 charging modes (Solar Only, Utility First, or Solar&Utility) and 2 output modes (Solar First, Utility First). In Solar Priority Mode, the inverter maximizes solar energy utilization by intelligently switching between utility and battery, based on a set battery voltage point.
-
【Applications】This solar inverter can power all kinds of appliances in the home or office environment, including motor appliances such as tube light, fan, refrigerator and air conditioning.
-
【Can Work No Battery】
Specification
Table 1 Line Mode Specifications |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Input Voltage Waveform |
Pure Sine Wave(Utility or Generator) |
|
Nominal Input Voltage |
230Vac |
|
Max AC Input Voltage |
300Vac |
|
Nominal Input Frequency |
50Hz/60Hz(Auto detection) |
|
Efficiency(Line Mode) |
>95%( Rated R load,battery full charged) |
|
Transfer Time |
10ms typical(UPS); 20ms typical(Appliances) |
|
Table 2 Inverter Mode Specifications |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Rated Output Power |
4.2KW |
6.2KW |
Output Voltage Waveform |
Pure Sine Wave |
|
Output Voltage Regulation |
230Vac±5% |
|
Output Frequency |
50Hz |
|
Peak Efficiency |
93% |
|
Overload Protection |
3s@≥150% load;5s@101%~150% load |
|
Surge Capacity |
2* rated power for 5 seconds |
|
Nominal DC Input Voltage |
24Vdc |
48Vdc |
Cold Start Voltage |
23Vdc |
46.0Vdc |
No Load Power Consumption |
35W |
50W |
Table 3 Charge Mode Specifications |
||
Utility Charging Mode |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Charging Algorithm |
3-Step |
|
AC Charging Current (Max) |
100A |
|
MPPT Solar Charging Mode |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Max. PV Array Power |
6200W |
6500W |
Nominal PV Voltage |
240Vdc |
360Vdc |
PV Array MPPT Voltage Range |
60Vdc~450Vdc (Battery connected) 90Vdc~450Vdc (No Battery connected) |
90Vdc~500Vdc (Battery connected) 120Vdc~500Vdc (No Battery connected) |
Max. PV Array Open Circuit Voltage |
500Vdc |
|
Max Charging Current (AC charger+solar charger) |
120A |
|
Tabel 4 Grid-Tie Operation |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Nominal Output Voltage |
220/230/240VAC |
|
Feed-in Grid Voltage Range |
195-253VAC |
|
Feed-in Grid Frequency Range |
49-51±1Hz/59-61±1Hz |
|
Nominal Output Current |
18.2A |
26.9A |
Maximum Conversion Efficiency(DC/AC) |
97% |
|
Table 5 Two Load Output Power |
||
INVERTER MODEL |
4.2KW |
6.2KW |
Full Load |
4200W |
6200W |
Maximum Main Load |
4200W |
6200W |
Maximum Second Load(battery model) |
1400W |
2066W |
Main Load Cut Off Voltage |
26VDC |
52VDC |
Main Load Return Voltage |
27VDC |
54VDC |
Important note:
Please do not select the mains priority as output priority after connecting the device to two-phase 220V/230V to avoid potential safety risks for the device. Do not connect the AC output end of the device to a saving transformer to not affect the normal life of the device.
Tips:
What kind of inverter is suitable for your devices?
Electrical devices are divided into two categories: resistive load and inductive load.
If you need the inverter to operate the resistive load (e.g. Laptop, TV, electric stove), please choose the inverter with a continuous power higher than the rated power of the device, and best use 80% of the rated power.
If you use a microwave oven, water pump, air conditioning and other devices with motor or compressor, please choose the inverter whose continuous power is 3-10 times higher than your device.
NOTE :
The battery capacity of the correct matching system is determined according to the specific usage requirements of the load and application scenarios, otherwise it will easily lead to insufficient battery capacity or excessive waste of power generation. For details, please refer to the manual recommendation or consult us.
Reviews